Changes

MyWikiBiz, Author Your Legacy — Sunday November 24, 2024
Jump to navigationJump to search
no edit summary
Line 28: Line 28:  
[[Directory:BRL Test|<go back to BRL Test Home Page on MyWikiBiz]]
 
[[Directory:BRL Test|<go back to BRL Test Home Page on MyWikiBiz]]
 
== HP 8510C Network Analyzer Agilent [8510C] 110GHz==
 
== HP 8510C Network Analyzer Agilent [8510C] 110GHz==
[[8510C_Network_Analyzer.JPG‎‎‎|left]]
+
[[image:8510C_Network_Analyzer.JPG‎‎‎|left]]
'''HP 8510C Network Analyzer Agilent 8510C.''' Premium Used . BRL Test, established 2001, is happy to offer this proven network analyzer. Fully calibrated with CERT. You have the added reassurance of warranty and right of return. We boast a 100% satisfaction rating. <p>The 8510C vector network analyzer continues to provide the best performance to meet your new design and test challenges. With unmatched accuracy and convenience, the 8510C vector network analyzer makes broadband measurements from 45 MHz to 50 GHz in 2.4 mm coax, from 45 MHz to 110 GHz in 1.0 mm coax and from 33 GHz to 110 GHz in waveguide bands.
+
'''HP 8510C Network Analyzer Agilent 8510C.''' Premium Used . BRL Test, established 2001, is happy to offer this proven network analyzer. Fully calibrated with CERT. You have the added reassurance of warranty and right of return. We boast a 100% satisfaction rating. For a quote visit our website page [http://www.brltest.com/index.php?main_page=product_info&cPath=27_2706&products_id=3863/ 8510C] <p>The HP 8510C vector network analyzer continues to provide the best performance to meet your new design and test challenges. With unmatched accuracy and convenience, the 8510C vector network analyzer makes broadband measurements from 45 MHz to 50 GHz in 2.4 mm coax, from 45 MHz to 110 GHz in 1.0 mm coax and from 33 GHz to 110 GHz in waveguide bands.
    
The 8510C network analyzer measures the magnitude, phase, and group delay of two-port networks to characterize their linear behavior. Optionally, the 8510C network analyzer is also capable of displaying a network’s time domain response to an impulse or a step waveform by computing the inverse Fourier transform of the frequency domain response. The 8510C family of systems is modular. Choose the source(s), S-parameter test set(s), and test accessories to meet your measurement applications.<BR>Thru-Reflect-Line precision two-port calibration for coaxial measurements<br>
 
The 8510C network analyzer measures the magnitude, phase, and group delay of two-port networks to characterize their linear behavior. Optionally, the 8510C network analyzer is also capable of displaying a network’s time domain response to an impulse or a step waveform by computing the inverse Fourier transform of the frequency domain response. The 8510C family of systems is modular. Choose the source(s), S-parameter test set(s), and test accessories to meet your measurement applications.<BR>Thru-Reflect-Line precision two-port calibration for coaxial measurements<br>
Line 41: Line 41:  
Four S-parameter color display<br>
 
Four S-parameter color display<br>
 
Modular to configure to your needs <p>
 
Modular to configure to your needs <p>
 +
'''Repair of Agilent HP 8510C'''<BR>  BRL Test in House Repair Engineering Group absolutely knows HP 8510C Repair.  Call 407-682-4228 for service.
 
[http://brltest.com/ BRL Test website]
 
[http://brltest.com/ BRL Test website]
 
[http://www.brltest.com/ BRL Test website]
 
[http://www.brltest.com/ BRL Test website]
463

edits

Navigation menu