Standard Options 8712B<br>
[http://brltest.com/ BRL Test website]
+
75 ohms (Option 1EC) <br>
 +
Provides 75 ohm system impedance.
 +
AM delay (Option 1DA/1DB)
 +
This option adds amplitude modulation group
 +
delay capability, which allows measurements of
 +
group delay through frequency-translation devices
 +
such as tuners or mixers. Using two external scalar
 +
detectors (86200B or 86201B) and a power splitter
 +
(all included) this option measures group delay in
 +
any device that does not have limiting circuits, saturated amplifiers, or automatic gain control.<br>
 +
Option 1DA is for a 50 ohm 8712B or 8714B.<br>
 +
Option 1DB is for a 75 ohm 8712B or 8714B.<br>
 +
IBASIC (Option 1C2)
 +
This option adds a resident BASIC system controller, facilitating automated measurements and
 +
control of other devices. Using keystroke recording
 +
for the simplest applications, or an optional keyboard to write complex control and calculation
 +
programs, IBASIC improves productivity by customizing your measurements.<br>
 +
Step attenuator (Option 1E1)
 +
This option adds a built-in 60 dB step attenuator,
 +
extending the source output power low-end range
 +
to –60 dBm.<br>
 +
Fault location and structural return loss software (Option
 +
100)
 +
For fully characterizing cable performance, this
 +
software package provides both fault location and
 +
structural return loss. Structural return loss is a
 +
special case of return loss measurements. Physical
 +
damage of cable, by handling or manufacturing
 +
process, causes reflections. Structural return loss
 +
occurs when these periodic reflections sum at halfwavelength spacing and reflect the input signal.<br>
 +
Special Options<br>
 +
Switching test sets (Special Option K02)
 +
Switching test sets enhance productivity by allowing multiple measurements with a single connection to the device under test. They are available in
 +
several configurations<br>
 +